Pressure Sensor type: Absolute pressure sensors Connector type: Standard 1/4" and 3/8" NPT male flare fitting Range: 29” HgV to 580psig (English), 74 cmHgV to 0 to 4000KPa (Metric), 4.000MPa (Metric), and 40.00bar (Metric) Resolution: 0.1 psi/inHg; 1 kPa/cmHg; 0.001MPa; 0.01bar Accuracy: 29” HgV to 0” HgV: ±0.2” HgV 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa: ±0.007MPa; 0 to 13.78 bar ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa); 13.78 to 40.00bar: ±(0.3% of reading +0.07bar) Maximum overload pressure: 800 psig Units: Psig, kPa, MPa, bar, inHg, and cmHg
Temperature Sensor type: Type K thermocouple Range: -95°F to 999.9°F (-70°C to 537.0°C) Resolution: 0.1°F/°C Accuracy: ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C ±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C Note: All accuracies are after a field calibration.
General
Mini-USB port: For updating to newer versions of firmware Display size: 5 inches (diagonal) Backlight: Blue (On for 3 minute unless turned off manually) Battery: 6 x AA (Battery life below based on alkaline type) Battery life: 350 hours (without vacuum, backlight and wireless) Low battery indication: is displayed when the battery voltage drops below the operating level Auto shut off: 30 minutes of inactivity when APO is activated Over range: "OL" or "-OL" is displayed Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH Temperature coefficient: 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) Weight: 4.03 lbs (1.83 kg)
Wireless Wireless range: 1 to 100 feet (30m) Initial sync setup range: 1 to 10 feet Wirelessly transmit to Fieldpiece HVAC Guide® HG3 System Analyzer Wirelessly receive indoor wet bulb (IDWB) and outdoor dry bulb (ODDB) from Fieldpiece transmitters |