Hioki 3390-10 Power Analyzer - High Accuracy

$0.00
Mitchell Part Number
HKJ-3390-10
Manufacturer
Availability
Out of Stock
Quick overview
Discontinued
  1. Measurement accuracy of up to ±0.1% when used with certain pass-through current sensors
    The 3390-10 achieves a maximum measurement accuracy of ±0.1% when used with certain HIOKI pass-through current sensors, making the new instrument more precise than the 3390, whose accuracy peaks at ±0.16%. High precision on the order of 0.1% is required in the development of products for energy conservation and other applications, and the 3390-10 delivers the performance necessary to meet those needs.
  2. Range-independent accuracy
    While the base model 3390’s accuracy depends on the range being used, all of the 3390-10’s ranges share the same accuracy, allowing users to measure current and power without worrying about which range they are using.
  3. Extended period of guaranteed accuracy (from 6 months to 12 months)
    Whereas the 3390’s accuracy is guaranteed for 6 months, the 3390-10 features a 12-month period of guaranteed accuracy. Additionally, the 9791 MOTOR TESTING OPTION, 9792 D/A OUTPUT OPTION, and 9793 MOTR TESTING & D/A OUTPUT OPTION share the same 12-month period of guaranteed accuracy.
More Information
Weight 15.000000
Specifications
Accuracy Specifications
  Voltage Current Active power
DC ±0.07% rdg. ±0.1% f.s. ±0.07% rdg. ±0.1% f.s. ±0.07% rdg. ±0.1% f.s.
45 Hz to 66 Hz ±0.05% rdg. ±0.05% f.s. ±0.05% rdg. ±0.05% f.s. ±0.05% rdg. ±0.05% f.s.
 
In the above frequency range, accuracy applies to use of the instrument with dedicated current measurement options (f.s. indicates the 3390-10 range). Values provided for voltages of 1,000 V and greater and active power are provided as reference values.
 
  Voltage Current Active power
0.5 Hz to 30 Hz ±0.1% rdg. ±0.2% f.s. ±0.1% rdg. ±0.2% f.s. ±0.1% rdg. ±0.2% f.s.
30 Hz to 45 Hz ±0.1% rdg. ±0.1% f.s. ±0.1% rdg. ±0.1% f.s. ±0.1% rdg. ±0.1% f.s.
66 Hz to 1 kHz ±0.1% rdg. ±0.1% f.s. ±0.1% rdg. ±0.1% f.s. ±0.1% rdg. ±0.1% f.s.
1 kHz to 10 kHz ±0.2% rdg. ±0.1% f.s. ±0.2% rdg. ±0.1% f.s. ±0.2% rdg. ±0.1% f.s.
10 kHz to 50 kHz ±0.3% rdg. ±0.2% f.s. ±0.3% rdg. ±0.2% f.s. ±0.4% rdg. ±0.3% f.s.
50 kHz to 100 kHz ±1.0% rdg. ±0.3% f.s. ±1.0% rdg. ±0.3% f.s. ±1.5% rdg. ±0.5% f.s.
100 kHz to 150 kHz ±20% f.s. ±20% f.s. ±20% f.s.
 
For current and active power in the above frequency ranges, the current sensor’s accuracy must be added to the above accuracy figures. Values provided the following are provided as reference values:
  • Voltage, current, and active power from 0.5 Hz to 10 Hz
  • Voltages in excess of 220 V and active power from 10 Hz to 16 Hz
  • Voltages in excess of 750 V and active power from 30 kHz to 100 kHz
  • Voltages in excess of (22,000/f [kHz]) V and active power from 100 kHz to 150 kHz
  • Active power and voltages of 1,000 V and greater