The Fluke 773 milliamp process clamp meter calibrator measures clamp loop currents, measures/sources mA in circuit and measures/sources up to 10 Volts DC. Also features a scaled milliamp display and simultanious mA in mA out...

    *  Best in class 0.2 % accuracy
    * 0.01 mA resolution and sensitivity
    * Measure 4 to 20 mA signals without ”breaking the loop”
    * Measure mA signals for PLC and control system analog I/O
    * Dual backlit display with both mA measurement and percent of 4 to 20 mA span
    * Measurement Spotlight illuminates hard to see wires in dark enclosures
    * Detachable clamp with extension cable for measurements in tight locations
    * Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
    * Automatically change the 4 to 20 mA output for remote testing
    * Power saving features, auto-off, backlight timeout extend battery life
    * Hold function captures and displays changing measurements
    * Measure 4 to 20 mA signals with in-circuit measurement
    * Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
    * Source 4 to 20 mA signals for testing control system I/O or I/Ps
    * mA output linear ramp or 25% step output
    * Automatically change the 4 to 20 mA output for remote testing
    *  DC voltage measurement to verify 24V power supplies or voltage I/O signals
    * Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
    * Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
          o Enables milliamp signal logging to a separate logging device without breaking the loop
          o Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
    * mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
          o Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
    * Voltage output linear ramp or 25% step output
          o Automatically change the voltage output for remote testing

 

More Information
Weight 1.200000
Product Includes * Soft Carrying Case * Users Manual
Specifications

Current Measurement Range by clamp: 0-20.9mA or 0-99.99 mA
Current Measurement Range by leads: 0-24 mA
Current Source Range: 0-24mA
Voltage Measuremnt Range: 0-30Vdc
Voltage Source Range: 0-10Vdc
Measurement Accuracy: 0.2% of reading ±5 digits
Best Measurement Resolution: 0.01 mA
Operating Temperature: -10 to 50 °C
Storage Temperature: -25 to 70 °C
Operation Humidity: < 90 % @ <30 °C, <75 % @ 30 to 50 °C
Power Supply: two “AA” alkaline batteris (45 hours typical operation)
Standards Met: all applicable requirements in EN 61326-1
Measurement Catagory: IEC 61010-1, CAT II 300 V

size 2.32 x 1.5 x 8.35 in.
Power Supply (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
Manufacturer Fluke
MPN FLUKE-773
Manufacturer Warranty Three years for electronics one year for cable and clamp assembly
Mitchell Catalog Number 9C773JF
upc code 095969475822
You're reviewing: Fluke 773 Milliamp Process Clamp Meter Calibrator