Product Includes |
Insulation Multimeter, Remote probe, Test leads, Alligator clips, K-type thermocouple, Hard case, Four AA alkaline batteries, Quick Reference Guide, CD Rom with Manual |
Specifications |
AC voltage measurement Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ ¹ 1 kHz bandwidth Low-Pass Filter Voltage Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) DC Voltage Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 6.000 V dc 0.001 V ±(0.09% + 2) 60.00 V dc 0.01 V ±(0.09% + 2) 600.0 V dc 0.1 V ±(0.09% + 2) 1000 V dc 1 V ±(0.09% + 2) Input impedance 10 MΩ (nominal), <100 pF Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range DC Millivolts Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 600.0 mVdc 0.1 mV ±(0.1% + 1) DC and AC Current Measurement AC 45 Hz to 1000 Hz Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. ¹ 1 kHz bandwidth Ohms Measurement Range Resolution Accuracy +(% of Rdg+Counts)¹ 600.0 Ω 0.1 Ω ±(0.9% + 2) 6.000 kΩ 0.001 kΩ ±(0.9% + 2) 60.00 kΩ 0.01 kΩ ±(0.9% + 2) 600.0 kΩ 0.1 KΩ ±(0.9% + 2) 6.000 MΩ 0.001 MΩ ±(0.9% + 2) 50.0 MΩ ² 0.01 MΩ ±(1.5% + 3) Overload protection 1000 V rms or dc Open circuit test voltage <8.0 V dc Short circuit current <1.1 mA ¹ Accuracies apply from 0% to 100% of range ² Up to 80% relative humidity Diode Test Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current: Accuracy ±(2% + 3) Continuity Test Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω Open circuit voltage <8.0 V Short circuit current 1.0 mA typical Overload protection 1000 V rms Response time >1 m sec Frequency Measurement Range Resolution Accuracy ±(% of Rdg+Counts) 99.99 Hz 0.01 Hz ±(0.1% + 1) 999.9 Hz 0.1 Hz ±(0.1% + 1) 9.999 kHz 0.001 kHz ±(0.1% + 1) 99.99 kHz 0.01 kHz ±(0.1% + 1) Frequency Counter Sensitivity 600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 mV V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 150.0 mV DC Trigger Levels¹ to 20 kHz² NA 6.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 1.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 1.5 V DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V 60.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 10.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 36.0 V DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V 600.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V 1000.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 300.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy ² Usable to 100 kHz with full scale input Capacitance Range Resolution Accuracy ±(% of Rdg+Counts) 1000 nF 1 nF ±(1.2% + 2) 10.00 μF 0.01 μF ±(1.2% + 2) 100.0 μF 0.1 μF ±(1.2% ±90 counts) 9999 μF 1 μF ±(1.2% ±90 counts) Temperature Measurement Range Resolution Accuracy ±(% of Rdg+Counts)¹ -40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts) -40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts) ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument Insulation Specifications Measurement range 0.01 MΩ to 2 GΩ Test voltages 50, 100, 250, 500, 1000 V Test voltage accuracy +20%, -0% Short-circuit test current 1 mA nominal Auto discharge Discharge time <0.5 second for C = 1 μF or less Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test Maximum capacitive load Operable with up to 1 μF load Output Voltage 50 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 50.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 100 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 60 to 100 MΩ Resolution 1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 250 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 250 MΩ Resolution 1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 500 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 500 MΩ Resolution 1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 600 MΩ Resolution 1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 0.6 to 2.0 GΩ Resolution 100 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts) General Specifications Maximum voltage applied to any terminal and common 1000 V Storage temperature -40 °C to 60 °C (-40 °F to 140 °F) Operating temperature -20 °C to 55 °C (-4 °F to 131 °F) Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) Relative humidity Noncondensing 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Radio frequency communication 2.4 GHz ISM Band Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE |