The Ideal Industries 61-955 SureTest Circuit Tracer is a powerful, versatile, easy-to-use troubleshooting test tool for finding breakers and hidden wire problems in residential/commercial/industrial environments. This tracer works on closed (energized) and open (de-energized) circuits. It identifies circuit breakers, find opens and shorts, and traces wires behind walls. The 955 kit has a Receiver (RC-955) with a 7-digit LED screen and a Hard Case (C-955) along with the transmitter (TR-955) and test lead kit (TL-956).

Key Features


• Numeric value and variable audible for easy-to-understand tracing
• Super-bright display for easy-viewing
• Peak detecting bar graph for instantaneous changes in signal strength
• Identifies breakers and fuses
• Pinpoints opens and shorts
• Traces wires behind walls
• Can be used on de-energized/energized circuits from 0-600V AC/DC
• Will not affect GFCIs or other sensitive equipment on the line
• Low battery indicator
• Cat III-600V safety rating

More Information
Weight 7.000000
Product Includes Transmitter (TR-955), Receiver (RC-955), Test Lead Kit (TL-956) and Carrying Case
Specifications

Locating Circuit Breakers and Fuses
Applications include identifying the breaker that protects the circuit under test, finding the correct breaker to de-energize the circuit, and labeling a breaker panel.
1) Connect the transmitter to the circuit that needs to be identified and power it on. The procedure is the same whether the circuit is energized or de-energized. But, a much stronger signal is produced using an energized (closed) circuit.
2) Turn on the receiver and go to the panel.
a) If more than one panel exists, set the receiver to Search Low (SL/2) mode and touch the nose to each panel cover until the panel with the strongest signal is identified.
b) If the receiver is detecting more than one panel with a strong signal, reduce the sensitivity range to Trace mode (TR/3), and repeat the step above.
3) Open the panel cover, set the receiver to Breaker (BR/4) mode. The receiver should be positioned on its side to orientate the antenna properly.
4) Slide the nose of the receiver down each breaker in the panel. The breaker with the highest numeric reading is the correct breaker. If two or more breakers have the same numeric values, tip the nose of the receiver up and then down at 45º angles and note the numeric values on each of the questionable breakers. Only the correct breaker will show a strong signal in all positions. Or, pull the panel cover, and place the nose on each of the individual hot wires for a more certain determination.
5) When the correct breaker is tripped (opened), the signal will drop significantly. And, the will disappear from the receiver’s display (RC-958 feature only). The LED on the transmitter will also turn off.

size 14.0 x 11.3 x 3.3 in. (355 x 285 x 83 mm)
Power Supply Eight 'AA' Batteries between Rx and Tx
Manufacturer Ideal
MPN 61-955
Manufacturer Warranty 2 Years
You're reviewing: Ideal 61-955 Sure Test Open/ Closed Circuit Tracer