Larkin M3K Power Semiconductor SCR and Diode Tester

$0.00
Mitchell Part Number
LAR-M3K
Availability
Out of Stock
Quick overview

Discontinued

Larkin M3K Power Semiconductor SCR and Diode Tester
  • Tests components according to JEDEC JC-22 and EIA RS-397 test standards
  • Components are tested for forward and reverse leakage current at voltages up to 3000V
  • Gate Voltage/Current to trigger is tested and displayed on the panel meters
  • Short current limited to 20mA for operator safety
  • Oscilloscope output provides the ability to observe the Voltage/Current curve on a X-Y oscilloscope.

Test Rotating Rectifier Modules

Make sure the Voltage Control is at the zero position (fully counter clockwise) before turning the unit on. Connect the Anode and Cathode leads to the diode to be tested. NOTE : Diodes only have to be tested in one direction. If the diode is forward biased (standard), the function switch should be in the PRV position. If the diode is reversed biased, the function switch should be in the PFV position

Place the function switch in the PRV (PFV) position and press the “TEST” button. Slowly increase the voltage while observing the Peak Voltage and Peak Leakage Current on the panel meters. In a properly functioning device, the rated voltage should be reached before the current starts to rise rapidly, (the “break-over point”).

Test Stud Mounted Diodes

Make sure the Voltage Control is at the zero position (fully counter clockwise) before turning the unit on. Connect the Anode and Cathode leads to the diode to be tested. NOTE : Diodes only have to be tested in one direction. If the diode is forward biased (standard), the function switch should be in the PRV position. If the diode is reversed biased, the function switch should be in the PFV position

Place the function switch in the PRV (PFV) position and press the “TEST” button. Slowly increase the voltage while observing the Peak Voltage and Peak Leakage Current on the panel meters. In a properly functioning device, the rated voltage should be reached before the current starts to rise rapidly, (the “break-over point”).

More Information
Switch Product Availability Message 5-7 weeks to Ship, Call if Urgent
Weight 25.000000
Product Includes tester, test leads and clamp assembly
Specifications

Specifications
Test Voltage: 0 to 3000 Volts AC
Short-Circuit Current: 20mA
Test Duration: max 15 seconds

Gate Voltage: 0 to 15 Volts
Power Supply: 115/220V 50/60Hz

size 16" x 8" x 8" (15 lbs)
Power Supply 120VAC with cord
Manufacturer Mitchell Instrument
MPN M3K
Manufacturer Warranty 1 Year
You're reviewing: Larkin M3K Power Semiconductor SCR and Diode Tester
Your Rating