Hioki PW3360-20/5000Pro KIT Three Phase Power Logger - 5000 Amp Flex Kit
Hioki PW3360-20/5000Pro KIT Three Phase Power Data Logger - the most simple and affordable power/energy demand logger
- Supports single to three-phase, 4-wire circuits- Simultaneously measure up to three single-phase,2-wire circuits (in the same power system).
- Measure up to 780V with a 1000V display range
- Broadly applicable for many jobs,including leakage current measurement with optional leakage current sensor
- Store months of data on SD cards
- QUICK SET function guides you in making the right connections.
- Freeware for Model PW3360-20 (free download from Hioki’s website) - Install the PW3360 Excel Graph Auto-Creation Software to create graphs in Excel automatically using recorded measurement data.
- Use Excel graph processing for before and after comparisons.
- PW3360 Setup and Download Software -> Use with a LAN or USB connection to download data recorded in the PW3360-20's internal memory or SD Card to a PC, and to change instrument settings from the PC.
Weight | 12.000000 |
---|---|
Product Includes | three 5000 Amp Flex current probes, four voltage leads with alligator clips, rechargeable battery pack, AC Adapter, USB cable, 2 GB SD memory card, instruction manual, hard carrying case and windows software |
Specifications | Input specifications Measurement line type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire,three-phase 4-wire Total display range: Within 0.4 to 130% of the range(zero is suppressed for less than 0.4%)Effective measurement range: Within 5 to 110% of the rangepeak: ±400% of range, however, maximum range is 200%. Power Ranges: 300.00 W to 9.0000 MW Depends on voltage/current combination and measured line type(see Measurement Range Configuration Tables) Total display range: Within 0 to 130% of the range (“0W” display indicates zero rms voltage and/or current) Effective measurement area: Within 5 to 110% of the range Measurement specifications
Measurement items:Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (consumption,regeneration), electricity rate display (by means of planned future function update), active power demand quantity (consumption,regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input Calculation selection: Power factor, reactive and apparent power: rms calculation/fundamental wave calculation Measurement accuracy (50/ 60Hz,power factor = 1): Voltage: ±0.3% rdg. ±0.1% f.s. Current: ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracyActive power: ±0.3% rdg. ±0.1% f.s. +clamp sensor accuracy. Clamp-On Sensor 9661 accuracy: ±0.3% rdg. ±0.01% f.s.(Accuracy depends on clamp sensor). Display update rate: Approx. 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) Measurement method: Digital sampling and zero cross synchronization calculation method. Sampling: 10.24 kHz (2048 points)Calculation processing50 Hz: Continuous, gapless measurement at 10 cycles 60 Hz: Continuous, gapless measurement at 12 cycles Recording specifications Data Save Locations:SD Card, internal memory (capacity: approx. 320 KB) Save interval time:1/2/5/10/15/30 seconds, 1/2/5/10/15/20/30/60 minutes* Available storage time is displayed on PW3360-20's setting screen Save items: Measurement save: Average only / all (average, maximum, minimum)Screen copy: ON/OFF (Saves the displayed screen as a BMP at a fi xedinterval.) The minimum interval time for saving screen copies is 5 min.If the setting is less than 5 min., screen copies will be saved every 5 min.Waveform save: Stores binary waveform data (with shortest interval 1 minute) Supported from version 2.00 Recording start methods: Interval time, manual, or at specifi ed time Recording stop methods: Manual, or at specifi ed time (up to one year) General specifications Display device: 3.5 inch TFT color LCD (320 × 240 pixel) Operating temperature and humidity(no condensation):-10°C to 50°C (14°F to 122°F), 80% RH or lessDuring LAN communication: 0°C to 50°C (32°F to 122°F), 80% RH or less. During battery operation: 0°C to 40°C (32°F to 104°F), 80% RH or less. During battery charging: 10°C to 40°C (50°F to 104°F), 80% RH or less Storage temperature and humidity(no condensation):-20°C to 60°C (-4°F to 140°F), 80% RH or less. However, the batteryُ s storage temperature range is -20°C to30°C (-4°F to 86°F), 80% RH or less Dielectric strength: 4.29 kVrms AC (1 mA sense current) between voltage input terminals and external terminals, 50/ 60 Hz for 60 sec. Applicable standards: Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3 Power supply: •Z1006 AC Adapter (12 V, 1.25 A), Rated supply voltage 100 VACto 240 VAC, Rated power supply frequency 50/60 Hz •Model 9459 Battery Pack (Ni-MH DC7.2 V 2700 mAh) Charge function:Charges the battery regardless of whether the instrument is on or off.Charge time: Max. 6 hr. 10 min. (reference value at 23°C) Maximum rated power:•When the Z1006 AC Adapter is used: 40 VA (including AC adapter),13 VA (PW3360-20 instrument only)•When the 9459 Battery Pack is used: 3 VA Continuous battery operation time:Approx. 8 hr. (Continuous, backlight off)(when using the battery pack) Backup battery life: Clock and settings (Lithium battery), Approx. 10 years @23°C (@73.4°F) Dimensions: Approx. 180W(7.09") × 100H(3.94") × 48D (1.89") mm (without PW9002)Approx. 180W(7.09") × 100H(3.94") × 68D (2.68") mm (with PW9002) Weight: Approx. 550g (19.4 oz) (without PW9002), Approx. 830g (29.3 oz) (with PW9002) Pulse input Input specifications: No-voltage contact input (counts when shorted terminals open) Voltage input (Hi: 2 V to 45 V, Lo: 0 V to 0.5 V, counts at Lo to Hi) Maximum rated input between terminals: 45 V DC Maximum rated input to ground: not isolated (GND is equipment common) Measurement range: 0 to 9999 (maximum pulse count per save interval) Filter: Filter On (for mechanical contacts) 25 Hz or less, and at least 20ms Hi and Lo pulse width Filter Off (for solid-state contacts) 5 kHz or less, and at least 100μs Hi and Lo pulse width Scaling: Displays product of pulse count and scaling factor settingSetting ranges: 0.001 to 1.000, and 1.000 to 100.00 Pulse output Function: Output pulse rate is proportional to active power consumption(WP+) when measuring integral power consumption Pulse rate:OFF/1Wh/10Wh/100Wh/1kWh/10kWh/100kWh/1000kWh(Default: 1 kWh) Pulse width: approx. 100 ms Output signal: Open-collector 30 V, 5 mA max (photocoupler isolated)Active Low External interfaces Specifications SD card Interface:Settings data, measurement data, screen dataWaveform data (support planned from version 2.00) LAN interface: 10BASE-T/100BASE-TX IEEE802.3 Compliance- HTTP server function- Download settings and data by communication application program USB interface: USB Ver 2.0, Windows 7 (32/64bit) / Vista (32bit) /XP- When connected to a computer, the SD Card and internalmemory are recognized as removable storage devices.- Download settings and data by communication application program |
size | 7.09" × 3.94" × 1.89" |
Power Supply | rechargeable battery pack or ac adapter |
Manufacturer | Hioki |
MPN | PW3360-20/5000Pro KIT |
Manufacturer Warranty | 1 Year |